E-Cue 660-12000
The E-Cue 660-12000 was especially designed for FAA Level D Full Flight Simulation and is an electric motion systems that is capable of handling a Gross Moving Load (GML) of 12,000 kg (26,500 lbs) and comprises six 60'' (1500 mm) stroke actuators.
Specification E-Cue model 660-12000
|
DOF |
Excursion Limits |
Velocity |
Acceleration |
|
Single DOF |
Maximum* |
|
Surge |
-1.14 / +1.40 m |
-1.40 / +1.40 m |
±1.0 m/s |
±7 m/s2 |
|
Sway |
±1.15 m |
±1.22 m |
±1.0 m/s |
±7 m/s2 |
|
Heave |
-1.00 / +0.98 m |
-0.92 / +1.06 m |
±0.8 m/s |
±8 m/s2 |
|
Roll |
±25° |
±29° |
±24 °/s |
>150 °/s2 |
|
Pitch |
-25° / +28° |
-32° / +36° |
±21 °/s |
>150 °/s2 |
|
Yaw |
±29° |
±31° |
±26 °/s |
>150 °/s2 |
* Envelope fully used with APK software only
Payload Data
|
Gross Moving Load (GML) |
12000 kg |
|
Payload |
11000 kg |
|
GML moment of Inertia about X-axis |
50000 kg m2 |
|
GML moment of Inertia about Y-axis |
50000 kg m2 |
|
GML moment of Inertia about Z-axis |
50000 kg m2 |
|
GML CoG above moving platform centroid |
1.5 m |
Geometry
|
Top of upper joint settled |
2.40 m |
|
Diameter ground frame |
6.02 m |
|
Actuator stroke |
1500 mm |
Power Consumption
|
Power requirements |
3 phase 400 VAC, 50/60 Hz |
|
Average power consumption |
30 KW |
|
Peak power consumption |
90 KW |
Electronics & Software
|
Motion control computer |
|
Maintenance & diagnostics laptop |
|
Motion software |
|
Ethernet UDP, Reflective Memory or SCRAM Net host interface |
Typical Simulation Applications
|
FAA Level C/D Full Flight simulation |
Example of a project featuring the E-Cue 660-12000

See other Moog FCS' Standard Systems >> E-Cue 624-1800
E-Cue 624-2800
E-Cue 636-4500
E-Cue 660-8000
E-Cue 304-G-seat